Flicker function

Wave form of the light source intensity. Possible settings are sine wave and square wave. Here the choice for the most popular lamptypes:

lamp type flicker
function
flicker
factor
HMI magnetic ballast: sine wave 40 - 70 %
Street lights magn. ballast: sine wave 50 - 70 %
Fluorescent magn. ballast: sine wave 30 - 60 %
Fluorescent elecr. ballast: sine wave 0 - 12 %
Household bulbs: sine wave 10 - 15 %
Tungsten lights sine wave 0 - 10 %
HMI electronic ballast: sine wave 1 -   3 %
Sunlight:   0 %
LED 100%, on transformers: sine wave 40 - 99 %
LED 100%, low cost supply: sine wave 0 - 15 %
LED 100%, quality supply: sine wave 0 -   3 %
LED dimmed at 50%: square 99 %